Protect Your Circuits Breaker using Circuit Breaker Timer
Save your Circuit Breakers
Take the circuit breaker timer kit that will safeguard you from unexpected incidents happening to the circuit breakers. Our designed safety equipment will test and find the exact fault of the circuit breakers and give the opportunity to rectify this. It will prevent damage that can occur because of faults. The device is also handy in saving itself from overload, so your work does not get delayed. The machine is suitable for indoor/Outdoor/LV/HV breakers of Various types and Coil Voltage 24V to 220V AC/DC. As the circuit breaker testing equipment suppliers in India we can ensure if anyone purchase this equipment they can handle private companies’ substations, metro substations, railway substations, and utility substations effortlessly.
Call Now: +91 94774-23085Latest
Related Products
Have a Full Control
LCD display to ease up operations
We equip the circuit breaker timer kit with an LCD display that will show you every piece of data about the testing arising on the device. There is also a printing facility available, so after complition of testing we also can print the values.There is also facility of Bounce Time measurement. We are circuit breaker testing equipment manufacturers in India ! So try this.
Parameters | Unit | Value |
Flow Rate | L/H | 600 |
Inlet Pump | L/M | 20 |
Outlet Pump | L/M | 20 |
Heating Power | KW | 9 |
Vacuum Pump | L/M | 200 |
Inlet/Outlet | mm | Φ12 |
Magnetic Strainer | Micron | 50 |
Secondary Filter | Micron | 2 No.10µ 2 No. 1µ |
Operation Temperature | ℃ | 40 ~ 70 (65°C is best) |
Power Supply | – | 390-450 VAC, 3 Phase, 50 Hz |
Ambient Temperature | ℃ | -25 ~ 55 |
Weight | KG | 350 |
Inlet/OutletHose Pipe | Meter | 10 Meter Each. |
Parameter | UsedOil | AfterTreatment |
Moisture(WaterContent) | ≥20 ppm | ≤ 5-10 PPM |
Gas Content | 10% | ≤0.1% (Vol) |
Particle size (Filtration Level) | 50-100 micron | ≤ 1 micron |
BreakdownVoltage(Dielectric) | 25 kV | ≥ 65KV |
- 0 to 9999.9 m sec.
- Resolution : 0.1 mS
- User select-able 3/4 pole measurement.
- Compact and lightweight instrument.
- Data download Windows based software.
- Built in Thermal Printer to PRINT test results.
- Small Portable, lightweight constructed in a suitcase for field use.
- Utility Substation.
- Railway Substation.
- Voltage 24 V to 220 V AC/DC.
- Indore Breakers of Private Companies and Metro Substation.
- Suitable for up to 220 KV Substation on Circuit Breaker Time testing.
- Suitable for Indoor/Outdoor/LV/HV Breaker of Various types and Coil
- Leads set
- Mains Cord.
- User Manual.
- Calibration certificate.
- Color Coded test probe set
- R, Y, B, COM : 8 meters each.
- Control Cable for ‘’+ve’’, Trip and Close : 5 meters each