Features Of DC HIGH VOLTAGE TEST SET
- High Voltage ‘ON’ Indication & Available in Manual / Motorized Mode & Timer for testing Time Setting(Optional) & Variable Test Voltage Setting Knob
- Selector switch for leakage current Setting(Optional) & Capable to test up-to 80 KV DC & KV Meter for High Voltage Measurement
- Short Circuit Protection & Easy to Operate & Relay Protection Zero Start Interlock Facility & mA Meter for leakage current measurement & Over Current Protection & HRC Fuse Protection
TECHNICAL SPECIFICATION
APPLICATION
CONTROL UNIT DETAILS
ACCESSORIES INCLUDED
TECHNICAL SPECIFICATION
MODEL | SBE – DCHV 30 | SBE – DCHV 40 | SBE – DCHV 50 | SBE – DCHV 60 | SBE – DCHV 70 | SBE – DCHV 80 |
OUTPUT VOLTAGE | 30 KV | 40 KV | 50 KV | 60 KV | 70 KV | 80 KV |
TRIPPING CURRENT FOR DC | 10 mA, 20 mA, 30 mA, 40 mA, 50 mA, 100 mA, | |||||
VOLTAGE ACCURACY | ± 2 % OF READING | |||||
VOLTAGE REGULATION | 1 KV | |||||
CURRENT ACCURACY | ± 2 % OF READING | |||||
CURRENT RESOLUTION | 1 mA | |||||
MAINS SUPPLY | 230 V, SINGLE PHASE / 400 V, TWO PHASE, 50 Hz, AC | |||||
DUTY | INTERMITTENT ( 5 MINUTES ON, 10 MINUTES OFF) | |||||
TIMER | 0 – 999 SEC | |||||
TIMER ACCURACY | ± 0.05 | |||||
OPERATION | MANUAL / MOTORIZED | |||||
COOLING | AIR NATURAL COOLED | |||||
INDICATION | INDICATION FOR MAINS ON & HT ON | |||||
PROTECTION | ZERO START INTERLOCK EARTH INTERLOCK M.C.B PROTECTION HRC FUSE PROTECTION RELAY PROTECTION OVERLOAD TRIPPING ARZANGEMENT | |||||
Units | 3 UNITS (CONTROL UNIT, HV TRANSFORMER, RECTIFIER UNIT) | |||||
OPERATING TEMP. | 0 ° C TO 55 ° C | |||||
HUMIDITY | 5 – 90 % |
APPLICATION
- Electrical Testing Laboratories
- Insulating Items Manufacturing Industries
- Cable Manufacturing and Repair Industries
- Motor Manufacturing and Repair Industries
- Pump Manufacturing and Repair Industries
- Engineering, Polytechnic and other Institutes
- Generator Manufacturing and Repair Industries
- Transformer Manufacturing and Repair Industries
CONTROL UNIT DETAILS
- Meters, Switches, Indicating Lamps, Push Button, Fuses etc. are fitted on the TOP of Control Panel Box.
- One Single Phase Copper double wound H.V Step up Graded Insulation is mounted in the Second unit
- HV DIODE, HV CAPACITOR, HV MEASURING RESISTANCE CHAIN IS PROVIDED AS SEPARATE UNIT.
- Contactor, Protection CT , wiring, One continuously variable Auto Transformer to vary the output voltage of suitable capacity are mounted inside the control box.
ACCESSORIES INCLUDED
- Discharge Rod.
- Operating Manual.
- Works Test Report.
- Warranty Certificate.
- 5 Meters Input Mains Power Cord.
- 5 Meter Interconnecting Cable for Testing Panel and DC Rectifier Unit.
- 5 Meter Interconnecting Cable for Testing Panel and High Voltage Transformer.
- Spare : 2 Nos. Fuses, 2 Nos. Push Button, 2 Nos. Indication Lamps, 1 No. Micro Switch, 2 Nos. Battery Terminals.