Measure Winding Resistance with Stable & Fast Resistance Meter
Stable Current Source for Measurement
The resistance meter will work effectively to 10 amperes of the current source. The meter is designed for Exceptionally Inductive objects, You can use the meter for the measurement of the winding resistance in the generators, motors, busbar contacts, power cables, transformers, and more. Just use the resistance meter supplier device today to have three types of tests to check a device. The one test can be related to the type of transformer you are using, the other test can be regarding the routine test, and the other test will be regarding the field test. The current source given in the meter is a highly durable source that won’t give you a challenge while testing the winding resistance.
Download CatalogueSpeedily Measurements are Now Easier
Every Transformer related business demands meters that can find the winding resistance at an ultra-fast speed. The product of the resistance meter manufacturers will not make you lose funds, as you will get maximum returns on your investments when the right calculations will be there. The meter will help you understand the data via the 4½ Digit LED/LCD Display.
- 4½ Digit LED / LCD Display.
- Stable & Fast Measurement.
- 0.1 µΩ Resolution on 2 MΩ range.
- True Four Terminal Measurement.
- Regulated and Highly Stable 10 Amp Current Source.
- Protection against Back E.M.F for high Inductive Loads.
- Test Laboratories.
- College Laboratories.
- Communication Cable.
- Instrumentation Cable.
- Component Manufacturing.
- Transmission and Distribution.
- Current Transformer Manufacturing.
- Transformer, Motors, Coil Manufacturing.
- User Manual.
- Mains Power Cord.
- One Set of Test Leads( 5 Meters) with Crocodile Clip (Optional: C – CLAMP)
- Printer.
- Data Save and Download.
RANGE | MAX. RADING | CURRENT | RESOLUTION | ACCURACY |
2 mΩ | 1.9999 mΩ | 10 A | 0.1 Ω | ± 0.5% of rdg ±5 Digit |
20 mΩ | 19.999 mΩ | 1A | 1Ω | ± 0.5% of rdg ±5 Digit |
200 mΩ | 199.99 mΩ | 1A | 10 Ω | ± 0.5% of rdg ±5 Digit |
2000 mΩ | 1.9999 Ω | 100 mA | 100 Ω | ± 0.5% of rdg ±5 Digit |
20 Ω | 19.999 Ω | 10 mA | 1 mΩ | ± 0.5% of rdg ±5 Digit |
200 Ω | 199.99 Ω | 1 mA | 10 mΩ | ± 0.5% of rdg ±5 Digit |
2000 Ω | 1999.9 Ω | 1 mA | 0.1 mΩ | ± 0.5% of rdg ±5 Digit |
POWER SUPPLY | 230 V AC, 50 Hz, Single Phase. |